| Sub Cat | Reactivity | Sensitivity | Detection Range | |
| MTS-1123-HM552 | Human | 7.8-500 pg/mL | Inquiry | |
| MTS-1123-HM553 | Mouse | 7.8-500 pg/mL | Inquiry | |
| MTS-1123-HM554 | Rat | 7.8-500 pg/mL | Inquiry | |
| MTS-1123-HM555 | Dog | 7.8-500 pg/mL | Inquiry | |
| MTS-1123-HM556 | Rabbit | 3.12 pg/mL-200 pg/mL | Inquiry | |
| MTS-1123-HM557 | Cow | 7.8-500 pg/mL | Inquiry | |
| MTS-1123-HM558 | Pig | 15.6 pg/mL-1000 pg/mL | Inquiry | |
| MTS-1123-HM559 | Chicken | 15.6 pg/mL-1000 pg/mL | Inquiry | |
| MTS-1123-HM560 | Guinea Pig | 7.8-500 pg/mL | Inquiry | |
| MTS-1123-HM561 | Horse | 7.8-500 pg/mL | Inquiry | |
| MTS-1123-HM562 | Monkey | 15.6 pg/mL-1000 pg/mL | Inquiry | |
| MTS-1123-HM563 | Golden Syrian Hamster | 7.8-500 pg/mL | Inquiry | |
| MTS-1123-HM564 | Cow | 1.56 pg/mL-100 pg/mL | Inquiry | |
| MTS-1123-HM565 | Rat | 1.56 pg/mL-100 pg/mL | Inquiry | |
| MTS-1123-HM566 | Human | 0.78 pg/mL-50 pg/mL | Inquiry | |
| MTS-1123-HM567 | Mouse | 1.56 pg/mL-100 pg/mL | Inquiry | |
| MTS-1123-HM568 | Goat | 15.62 pg/mL-1000 pg/mL | Inquiry | |
| MTS-1123-HM569 | Goat | 0.312 pg/mL-20 pg/mL | Inquiry | |
| MTS-1123-HM570 | Sheep | 1.56 pg/mL-100 pg/mL | Inquiry | |
| MTS-1123-HM571 | Rhesus Monkey | 40-10000 pg/mL | Inquiry |
Yes. This kit is a sandwich ELISA, colorimetric, and quantitative, and lists sample compatibility including serum, plasma, cell culture supernatant, tissue homogenate, and urine. For best results, treat each matrix carefully (clarify particulates, avoid hemolysis, standardize dilution), and consider running matrix-specific dilution checks to ensure your samples fall within the assay's usable signal range.
The kit uses a pre-coated plate, requires 100 µL sample volume, and the reported assay time is 1-4.5 hours depending on protocol choices. This flexibility is helpful when scheduling multiple plates. If throughput is the priority, set up consistent incubation timing across plates, prepare wash buffers in advance, and run standards/controls on every plate to maintain batch comparability.
Storage conditions are listed as 4°C and -20°C, with an expiry date of 6 months. For partial runs, avoid repeated freeze-thaw of sensitive reagents: aliquot reconstituted standards, keep detection reagents protected from contamination, and seal unused strips/plates tightly. These practices typically preserve performance when you spread experiments across weeks instead of running all 96 tests at once.
For Research Use Only. Do Not Use in Food Manufacturing or Medical Procedures (Diagnostics or Therapeutics). Do Not Use in Humans.